1
PRINTED IN U.S.A. 1004
PLACE THESE INSTRUCTIONS ADJACENT TO HEATER
AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE.
COMMERCIAL GAS WATER HEATER
Glass-Lined Tank-Type Water Heater
PART NO. 196284-001
• INSTALLATION • OPERATION • SERVICE • MAINTENANCE
Thank you for buying this energy efficient water heater. We
appreciate your confidence in our products.
CAUTION
TEXT IN BLACK BOLD TYPE OR UNDERLINED
CONTAINS INFORMATION RELATIVE TO YOUR
SAFETY. PLEASE READ THOROUGHLY BEFORE
INSTALLING AND USING THIS APPLIANCE.
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1

1PRINTED IN U.S.A. 1004PLACE THESE INSTRUCTIONS ADJACENT TO HEATERAND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE.COMMERCIAL GAS WATER HEATERGlass-Line

Seite 2 - FOREWORD

10FOR YOUR SAFETY READ BEFORE LIGHTINGBEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED AT FAUCETS.WARNING: If you do not follow

Seite 3 - TABLE OF CONTENTS

11FOR YOUR SAFETY READ BEFORE LIGHTINGBEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED AT FAUCETS.WARNING: If you do not follow

Seite 4 - CIRCULATING PUMP

12TEMPERATURE REGULATION DANGERTHIS WATER HEATER IS EQUIPPED WITH AN ADJUSTABLETHERMOSTAT TO CONTROL WATER TEMPERATURE. HOT WATERTEMPERATURES REQUIRE

Seite 5 - AIR REQUIREMENTS

13• If the back draft cannot be corrected by the normal method or ifa suitable draft cannot be obtained, a blower type flue gasexhauster must be emplo

Seite 6 - CAUTION

14TABLE 3.INPUT CHECK TIME REQUIRED TOCONSUME 1 CU. FT. OF GASApprox. Time RequiredType of BTU Per To Consume 1 Cu. Ft.Model Gas Cu. Ft. of Gas***-75

Seite 7 - GAS PIPING

15PREVENTIVE MAINTENANCERECOMMENDED PROCEDURE FOR PERIODICREMOVAL OF LIME DEPOSITS FROM TANKTYPE COMMERCIAL WATER HEATERSThe amount of calcium carbona

Seite 8 - CUBIC FEET PER HOUR

16Prepare the Water HeaterTo delime the water heater using the Flo-Jug method, first preparethe heater for deliming. Then install the long plastic ma

Seite 9 - OPERATION

17PLUG THE TEMPERATURE AND PRESSURE RELIEF VALVE.Also, the leakage could be due to unusually high waterpressures or temperatures in the system, or to

Seite 11

19NOTES

Seite 12 - CHECK VENTING

2FOREWORDThe design of models ***-75 and 100 comply with the latest versionof ANSI Z21.10.3-CSA 4.3 as automatic storage or automaticcirculating tank

Seite 14

3GENERAL SAFETYINFORMATIONPRECAUTIONSDO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDERWATER. Immediately call a qualified service technician to in

Seite 15 - PREVENTIVE MAINTENANCE

4IF YOU EXPERIENCE AN OUT-OF-GAS SITUATION, DO NOT TRY TORELIGHT APPLIANCES YOURSELF, ask your LP delivery person torelight pilots for you. Only trai

Seite 16 - CHECKLIST

5Drain pans suitable for these heaters are available from yourdistributor or Apcom Inc., 125 Southwest Parkway, Franklin,TN 37065 or contact them by p

Seite 17

6If the unconfined space is within a building of tight construction(buildings using the following construction: weather stripping, heavyinsulation, ca

Seite 18

7VENT CONNECTIONVent connections must be made to an adequate stack or chimney.Size and install proper size vent pipe. Do not reduce pipe size toless

Seite 19

8Size the main gas line in accordance with Table 1. The figuresshown are for straight lengths of pipe at 0.5 in. W.C. pressuredrop, which is considere

Seite 20

9 THERMOSTAT FOR NATURAL AND PROPANE GASESFIGURE 6.GAS PRESSURE REGULATORThe gas pressure regulator is built into the gas valve and isequipped